  Mainstream Gas Analyzer
 
 

The Squre One Mainstream Gas Analyzer is a very small, lightweight, high performance remote sensor. The Mainstream Analyzer measures multiple gas analytes including CO2 and N2O. Low cost sample cells make the Mainstream Analyzer an affordable solution for use in monitors, ventilators, and pulmonary test equipment.

A unique optically stabilized infrared detector and a regulated infrared source provide both accuracy and highly reliable performance. Optical stabilization eliminates moving parts and provides a stronger signal for more accurate analysis. Square One’s patented infrared source use a platinum RTD elecment and an electronic servo loop for tightly controlled temperatures - significantly reducing the need for recalibration.

   Detailed Specifications
 Pricing Information
 
 

 What are the detailed specifications for the Mainstream Gas Analyzer?
 Where do I buy one?

   
   

 What are the detailed specifications for the Ambient Gas Analyzer?

Measurement Method Mainstream NDIR
Package Size 2.0" X 0.75" X 1.0" = 1.5 cu. In.
Weight 1 oz.
Power Consumption 1.5 W, 12VDC
Operating Temperature 25 to 45 degrees C
Storage Temperature  -40 to 60 degrees C
Humidity 0 to 85% non-condensing
Measured Gases CO2 and N2O
Zero Drift CO2 < 1.25 mmHg / 24 hour (1.6% of full scale)(STSP)
Zero Drift N2O  < 4% / 24 hour (STSP)
Span Stability CO2 < 2 mmHg / year (STSP)
Span Stability NO2 < 4% / year (STSP)
Accuracy: CO2 +/- 3 mmHg 0-60 mmHg
+/- 5% of reading 61-100 mmHg
Accuracy: N2O +/-5% FS
Warm Up Time < 90 seconds to measure gases
< 30 minutes to full specification
Airway Adapter / Sample Cell polyethylene body with 15/22 mm ANSI standard tapers
proprietary plastic film windows reduce condensation problems
Re-Calibration Frequency one year
Response Time: CO2 100 mS. Max. (10-90%, 200 ml/min.)
Response Time: N2O 100 mS. Max. (10-90%, 200 ml/min.)
Range: CO2 0 to 100 mmHg
Range: N2O 0 to 100%
Noise: CO2 1.5 mmHg RMS
Noise: N2O 15 mmHg RMS
   